FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Repair Information
190 Director 2/64 Service Manual
6. Click Maintenance > Port Diagnostics. The Port Diagnostics dialog box
displays, as shown in Figure 47.
Figure 47: Port Diagnostics dialog box
7. Select a port or UPM card for test:
To select an individual port for test, type the port number (0 through 63)
in the Port Number field.
To select a UPM card for test, type the port number of any of the four
ports on the card in the Port Number field, then click All ports on card.
8. Click Internal Loop on the Diagnostics Test drop-down list.
9. Click Next. Beaconing initiates for the port or UPM card selected for test. At
the Hardware View, a yellow triangle displays at the top of the UPM card. At
the Port Diagnostics dialog box, the message Verify selected ports
are beaconing displays.
10. Verify beaconing is enabled, then click Next. The message Press START
TEST to begin diagnostics displays, and Next changes to Start
Test.