FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
FRU Removal and Replacement
228 Director 2/64 Service Manual
Factory Defaults
Table 24 lists the defaults for the passwords and IP, subnet, and gateway
addresses.
Table 24: Factory-set Defaults
Procedural Notes
Note: HAFM and Element Manager screens in this manual may not match the screens
on your server and workstation. The title bars have been removed, and the fields may
contain data that does not match the data seen on your system.
The following procedural notes are referenced as applicable. The notes do not
necessarily apply to all procedures in the chapter.
1. Before performing an FRU repair, read the removal and replacement
procedures for that FRU carefully and thoroughly to familiarize yourself with
the procedures, and to reduce the possibility of problems or customer down
time.
2. When performing procedures described in this chapter, follow all electrostatic
discharge (ESD) procedures, WARNING and CAUTION statements, and
statements listed in the preface of this manual.
3. After completing the steps of a detailed procedure that is referenced from
another procedure, return to the initial (referencing) procedure and continue to
the next step of that procedure.
4. After completing a replacement procedure, clear the event code reporting the
failure and the event code reporting the recovery from the Director 2/64 Event
Log (at the HAFM appliance), and extinguish the amber system error light-
emitting diode (LED) at the director front bezel.
Item Default
Customer password password
Maintenance password level-2
IP address 10.1.1.10
Subnet mask 255.0.0.0
Gateway address 0.0.0.0