FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
FRU Removal and Replacement
230 Director 2/64 Service Manual
The ESD grounding point for the rear of the chassis (1) is located at the bottom
center, directly below the maintenance port, as shown in Figure 73. Touch the
chassis once before performing any maintenance action, and once each minute
while removing or replacing FRUs.
Figure 73: ESD grounding point (rear)
Concurrent FRUs
Table 25 lists concurrent FRUs. Concurrent FRUs can be removed and replaced
while the director is powered on and operational. The table also lists ESD
precaution requirements (yes or no) for each FRU and provides hyperlinks to the
removal and replacement procedure.
1
Table 25: Concurrent FRU Names and ESD Requirements
Concurrent FRU Name
ESD Precaution
Requirement
Control processor card (“RRP: Redundant CTP2
Card” on page 231)
Yes
Universal port module card (“RRP: UPM Card”
on page 236)
Yes
Small form factor pluggable (SFP) optical
transceiver (“RRP: SFP Optical Transceiver” on
page 241)
No
UPM filler blank (“RRP: UPM Filler Blank” on
page 244)
No