FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
FRU Removal and Replacement
231Director 2/64 Service Manual
Non-Concurrent FRUs
Table 26 lists non-concurrent FRUs. Non-concurrent FRUs are removed and
replaced after the director is powered off. The table also lists ESD precaution
requirements (yes or no) for each FRU, and references the page number of the
removal and replacement procedure.
.
RRP: Redundant CTP2 Card
Use the following procedures to remove or replace a redundant CTP2 card (two
cards in the director) with the backup CTP2 card operational. A list of tools required
is provided.
Caution: Do not remove and replace a redundant CTP2 card if the backup
CTP2 card is not fully operational and director power is on. The director IP
address, configuration data, and other operating parameters will be lost.
Power supply (“RRP: Redundant Power Supply”
on page 245)
Yes
Serial crossbar assembly (“RRP: Redundant SBAR
Assembly” on page 248)
Yes
Fan module (“RRP: Redundant Fan Module” on
page 252)
Yes
Table 25: Concurrent FRU Names and ESD Requirements (Continued)
Concurrent FRU Name
ESD Precaution
Requirement
Table 26: Non-Concurrent FRU Names and ESD Precautions
Non-Concurrent FRU Name
ESD Precaution
Requirement
Power module assembly (“RRP: Power Module
Assembly” on page 255)
Yes
Backplane (“RRP: Backplane” on page 258) Yes