FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
FRU Removal and Replacement
247Director 2/64 Service Manual
3. Orient the power supply with the cam lever disengaged and pulled out, as
shown in Figure 78.
a. Insert the power supply into the director chassis guide, then push the
power supply toward the backplane to engage the connector pins.
b. Push the cam lever in and to the left to cam the power supply into the
director chassis. Ensure the locking pin is engaged in the cam lever.
4. Disconnect the ESD wrist strap from the director chassis and your wrist.
5. Inspect the power supply to ensure the green PWR OK LED is illuminated
and all amber LEDs are extinguished. If a problem is indicated, go to “MAP
0000: Start MAP” on page 46 to isolate the problem.
6. At the Hardware View, click Logs > Event Log. The Event Log displays.
Ensure an event code 207 (power supply installed) displays in the log.
If an event code 207 does not display in the log, go to “MAP 0000: Start
MAP” on page 46 to isolate the problem.
7. Perform one of the following to verify power supply operation:
— At the Hardware View, observe the graphic representing the replacement
card and ensure no alert symbols display that indicate a failure (yellow
triangle or red diamond). If a problem is indicated, go to “MAP 0000:
Start MAP” on page 46 to isolate the problem.
— At the EWS interface, open the Switch tab at the View panel and ensure
no amber LEDs illuminate that indicate a power supply failure. If a
problem is indicated, go to “MAP 0000: Start MAP” on page 46 to isolate
the problem.
8. At the Hardware View, double-click the graphic representing the replacement
power supply to open the FRU Properties dialog box. Verify that information
(FRU name, position, and state) is correct. If a problem is indicated, go to
“MAP 0000: Start MAP” on page 46 to isolate the problem.
9. Perform the data collection procedure (
“Collecting Maintenance Data” on
page 197
).
10. Perform one of the following to clear the system error (ERR) LED:
— If at the HAFM application, open the Hardware View and:
a. Right-click the front panel bezel graphic (away from an FRU) to open
a menu.
b. Click Clear System Error Light.