FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
FRU Removal and Replacement
255Director 2/64 Service Manual
RRP: Power Module Assembly
Use the following procedures to remove or replace the power module assembly. A
list of tools required is provided.
Tools Required
The following tools are required to perform these procedures.
■ Standard flat-tip screwdriver.
■ Standard cross-tip (Phillips) screwdriver.
■ ESD grounding cable and wrist strap.
Removing a Power Module Assembly
To remove the power module assembly:
1. Notify the customer the director will be powered off. Ensure the customer’s
system administrator quiesces Fibre Channel frame traffic through the
director and sets attached devices offline.
2. If the director is installed in a stand-alone configuration, go to step 3. If the
director is rack-mounted, unlock and open the cabinet front and rear doors as
directed by the customer representative.
3. Power off and unplug the director (“Power-Off Procedure” on page 201).
WARNING: Ensure both power cords are disconnected from the power
module assembly prior to removal or replacement.
4. Follow ESD procedures by attaching a wrist strap to an approved bench
grounding point and your wrist.
Caution: To avoid causing machine errors or damage while working on the
director, follow ESD procedures by connecting a grounding cable to an
approved bench grounding point and wearing an ESD wrist strap.
5. Unseat and disconnect (but do not remove) both power supplies (“RRP:
Redundant Power Supply” on page 245).
6. Remove the RFI shield.