FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

319Director 2/64 Service Manual
B
Event Code Tables
An event is an occurrence (state change, problem detection, or problem
correction) that requires user attention or that should be reported to a system
administrator or service representative. An event usually indicates a switch
operational state transition, but may also indicate an impending state change
(threshold violation). An event may also provide information only, and not
indicate an operational state change. Events are reported as event codes.
This appendix lists all three-digit Director 2/64 event codes and provides detailed
information about each code. Event codes are listed in numerical order and in
tabular format, and are grouped as follows:
000 through 199—system events
200 through 299—power supply events
300 through 399—fan module events
400 through 499—control processor (CTP) card events
500 through 599—fiber port module (UPM) card events
600 through 699—serial crossbar (SBAR) assembly events
800 through 899—thermal events
Events are recorded in the Director 2/64 Event Log at the HAFM appliance, in the
Event Log of the Embedded Web Server interface, at a remote workstation if
e-mail and call-home features are enabled, at a Simple Network Management
Protocol (SNMP) workstation, or at a host console if inband management is
enabled. An event may also illuminate the system error light-emitting diode
(LED) on the director front bezel.
In addition to numerical event codes, the tables in this appendix also provide:
Message—a brief text string that describes the event.