FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Event Code Tables
326 Director 2/64 Service Manual
Event Code: 060
Message: Fabric Controller unable to synchronize databases.
Severity: Minor.
Explanation: Following a CTP2 card reset or replacement, the Fabric Controller attempted to
acquire an up-to-date copy of its databases from the other CTP2 card, but failed. All
Fabric Controller databases are initialized to an empty state, resulting in a
momentary loss of interswitch communication capability.
Action: Perform the data collection procedure and return the backup CD to HP support
personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔
Event Code: 061
Message: Fabric Controller database invalid.
Severity: Minor.
Explanation: Following a CTP2 card failover or replacement, IML, or firmware download, the
Fabric Controller database failed its CRC validation. All Fabric Controller databases
are initialized to an empty state, resulting in a momentary loss of interswitch
communication capability.
Action: Perform the data collection procedure and return the backup CD to HP support
personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔