FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Event Code Tables
330 Director 2/64 Service Manual
Event Code: 071 (Continued)
Event Data
(Continued):
4 = Build fabric protocol error. A protocol error was detected during incorporation of
the Director 2/64 into the fabric. Disconnect the E_Port link, then reconnect the link.
If the condition persists, perform the data collection procedure and return the backup
CD to HP support personnel.
5 = No principal switch. No director or switch in the fabric can become the principal
switch. Modify the switch priority to any value other than 255.
6 = No response from attached switch (hello timeout). The Director 2/64
periodically verifies operation of attached fabric elements (directors or switches). The
director E_Port (at the operational director) times out and segments if the attached
device does not respond. Check the status of the attached director or switch. If the
condition persists, perform the data collection procedure (at the attached device)
and return the backup CD to HP support personnel.
7 = ELP retransmission failure timeout. A Director 2/64 that exhibits a hardware or
link failure attempted to join a fabric and transmitted multiple ELP frames to a fabric
element (director or switch). However, because of the problem, the director did not
receive responses to the ELP frames, and did not receive an FLOGI frame. After five
ELP transmission attempts, the director E_Port (failed director) times out and
segments. Go to “MAP 0000: Start MAP” on page 46 to perform hardware fault
isolation at the failed director.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔