FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Event Code Tables
343Director 2/64 Service Manual
Power Supply Events (200 through 299)
Event Code: 200
Message: Power supply AC voltage failure.
Severity: Major.
Explanation: Alternating current (AC) input to the indicated power supply is disconnected or AC
circuitry in the power supply failed. The second power supply assumes the full
operating load for the director.
Action: Ensure the power supply is connected to facility AC power, and verify operation of
the facility power source. If the AC voltage does not recover (indicated by event code
203), replace the failed power supply. Perform the data collection procedure and
return the backup CD and failed power supply to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 201
Message: Power supply DC voltage failure.
Severity: Major.
Explanation: Direct current (DC) circuitry in the power supply failed. The second power supply
assumes the full operating load for the director.
Action: Replace the failed power supply. Perform the data collection procedure and return
the backup CD and failed power supply to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 202
Message: Power supply thermal failure.
Severity: Major.