FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Event Code Tables
347Director 2/64 Service Manual
Fan Module Events (300 through 399)
Event Code: 300
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: One cooling fan (out of six) failed or is rotating at insufficient angular velocity. The
remaining fans are operational. The amber LED illuminates at the rear of the fan
module associated with the failed fan.
Action: Replace the indicated fan module.
Event Data: The first byte of event data (byte 0) specifies the failed fan number.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 301
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Two cooling fans (out of six) failed or are rotating at insufficient angular velocity. The
remaining fans are operational. The amber LED illuminates at the rear of the fan
modules associated with the failed fans.
Action: Replace the indicated fan modules.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔