FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Event Code Tables
348 Director 2/64 Service Manual
Event Code: 302
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Three cooling fans (out of six) failed or are rotating at insufficient angular velocity.
The remaining fans are operational. The amber LED illuminates at the rear of the fan
modules associated with the failed fans.
Action: Replace the indicated fan modules.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 303
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Four cooling fans (out of six) failed or are rotating at insufficient angular velocity.
The remaining fans are operational. The amber LED illuminates at the rear of both
fan modules.
Action: Replace both fan modules
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔