FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Event Code Tables
356 Director 2/64 Service Manual
Event Code: 412
Message: CTP2 watchdog timer reset.
Severity: Informational.
Explanation: The hardware watchdog timer expired and caused the CTP2 card to reset.
Action: Perform the data collection procedure and return the backup CD to HP support
personnel.
Event Data: Byte 0 = reset type as follows: 00 = task switch did not occur within approximately
one second,
01 = interrupt servicing blocked for more than approximately one second.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 413
Message: Backup CTP2 card POST failure.
Severity: Major.
Explanation: A backup CTP2 card was installed in the director and failed POSTs.
Action: Replace the indicated CTP2 card with a functional card. Perform the data collection
procedure and return the backup CD and faulty card to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔