Event Code Tables
357Director 2/64 Service Manual
Event Code: 414
Message: Backup CTP2 card failure.
Severity: Major.
Explanation: The backup CTP2 card failed.
Action: Replace the indicated CTP2 card with a functional card. Perform the data collection
procedure and return the backup CD and faulty card to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 415
Message: Backup CTP2 card removed.
Severity: Informational.
Explanation: The backup CTP2 card was removed while the director was powered on and
operational.
Action: No action required or install an operational backup CTP2 card.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host