FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Event Code Tables
359Director 2/64 Service Manual
Event Code: 418
Message: User-initiated CTP2 card switchover.
Severity: Informational.
Explanation: The backup CTP2 card became the active CTP2 card after a user-initiated
switchover. The previously active CTP2 card is now the backup CTP2 card.
Action: No action required.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 420
Message: Backup CTP2 card non-volatile memory failure.
Severity: Major.
Explanation: The backup CTP2 card detected a non-volatile memory failure. The failure has no
impact on the active CTP2 card.
Action: Replace the indicated CTP2 card with a functional card. Perform the data collection
procedure and return the backup CD and faulty card to HP support personnel.
Event Data: Byte 0 = non-volatile memory area identifier.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔