FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Event Code Tables
361Director 2/64 Service Manual
Explanation: The HAFM appliance initiated download of a new firmware version to the director.
Action: No action required.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 426
Message: Multiple ECC single-bit errors occurred.
Severity: Minor.
Explanation: When the SDRAM controller detects an error checking and correction (ECC) error,
an interrupt occurs. If an interrupt occurs a certain number of times weekly, a 426
event code is recorded. The number of interrupts is indicated by the event data.
Action: No action required. SDRAM is probably malfunctioning intermittently.
Event Data: Byte 0 of the event data (equal to 5, 10, 15, or 20) is recorded. The number of
interrupts equals two to the power of the event data. Event data equal to 10 indicates
1,024 ECC error interrupts.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔