Event Code Tables
366 Director 2/64 Service Manual
Event Code: 442
Message: Embedded port anomaly detected.
Severity: Informational.
Explanation: The CTP2 card detected a deviation in the normal operating mode or status of the
embedded port.
Action: No action required. An additional event code is generated if this incident exceeds
an error threshold or results in a port failure.
Event Data: Byte 0 = port number.
Byte 1 = engineering reason code.port.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = high-availability error callout #1.
Bytes 10 and 11 = high-availability error callout #2.
Byte 12 = detecting port.
Byte 13 = connected port.
Byte 14 = participating SBAR assembly.
Bytes 16 and 17 = high-availability error callout #3.
Bytes 18 and 19 = high-availability error callout #4.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔