FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Event Code Tables
367Director 2/64 Service Manual
Event Code: 450
Message: Serial number mismatch detected.
Severity: Informational
Explanation: This event occurs when the sequence number or OEM serial number in the system
VPD (read from the backplane) does not match the sequence number and serial
number that were saved in NVRAM the last time the switch was IPLed. This event will
occur normally when a CTP2 is moved from one switch to the master position of
another switch. This event may occur abnormally when a hardware problem is
causing a problem reading the system VPD from the backplane.
Action: None. Any configured feature keys will be cleared, configuration information will be
synched with the backplane VPD, and the CTP2 will automatically be IPLed.
Event Data: Bytes 0-12 are the sequence number from the system VPD.
Bytes 13-31 are the OEM serial number obtained from the system VPD.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 451
Message: Switch speed incompatibility detected.
Severity: Informational
Explanation: The event occurs when the configured switch speed saved in NVRAM conflicts with
the speed capability of the switch. This event may occur when backup CTP2
hardware running an early version of software (below 1.3) is improperly
synchronized with a CTP2 operating at greater than 1Gb/s.
Action: None. Switch speed configuration and port speed configuration data will be set to a
level that is compatible with the CTP2 and the CTP2 will automatically be IPLed.
Event Data: None
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔