FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Event Code Tables
378 Director 2/64 Service Manual
Event Code: 513
Message: SFP optical transceiver hot-removal completed.
Severity: Informational.
Explanation: An SFP optical transceiver was removed while the director was powered on and
operational.
Action: No action required.
Event Data: Byte 0 = port number (0-127 and 132-143).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 514
Message: SFP optical transceiver failure.
Severity: Major.
Explanation: An SFP optical transceiver in a UPM card failed. The amber LED corresponding to
the port illuminates to indicate the failure. Other ports remain operational if their
LEDs are extinguished.
Action: Replace the failed transceiver with a functional transceiver of the same type.
Event Data: Byte 0 = port number (0-127 and 132-143).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔