FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Event Code Tables
385Director 2/64 Service Manual
Explanation: The indicated SBAR assembly is not recognized and displays as uninstalled to the
director firmware.
Action: Ensure the director model supports the operating firmware version. If the firmware
version is supported, replace the SBAR assembly with a functional assembly. Perform
the data collection procedure and return the backup CD and faulty assembly to HP
support personnel.
Event Data: Byte 0 = SBAR slot position (00 or 01).
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = detected module identifier.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔
Event Code: 607
Message: Director contains no operational SBAR assemblies.
Severity: Severe.
Explanation: The director firmware does not recognize an installed SBAR assembly.
Action: Install at least one functional SBAR assembly and power-on reset (POR) the director.
Event Data: Bytes 4 through 7 = elapsed millisecond tick count.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔