FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Event Code Tables
387Director 2/64 Service Manual
Thermal Events (800 through 899)
Event Code: 800
Message: High temperature warning (UPM card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a UPM card indicates the warm temperature
threshold was reached or exceeded.
Action: Replace the indicated UPM card with a functional UPM card of the same type.
Perform the data collection procedure and return the backup CD and faulty card to
HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 801
Message: Critically hot temperature warning (UPM card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a UPM card indicates the hot temperature
threshold was reached or exceeded.
Action: Replace the indicated UPM card with a functional UPM card of the same type.
Perform the data collection procedure and return the backup CD and faulty card to
HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔