FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Event Code Tables
388 Director 2/64 Service Manual
Event Code: 802
Message: UPM card shutdown due to thermal violation.
Severity: Major.
Explanation: An UPM card failed and was powered off because of excessive heat. This event
follows an indication that the hot temperature threshold was reached or exceeded
(event code 801).
Action: Replace the failed UPM card with a functional UPM card of the same type. Perform
the data collection procedure and return the backup CD and faulty card to HP
support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 805
Message: High temperature warning (SBAR assembly thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with an SBAR assembly indicates the warm
temperature threshold was reached or exceeded.
Action: Replace the indicated SBAR assembly with a functional assembly. Perform the data
collection procedure and return the backup CD and faulty assembly to HP support
personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔