FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Event Code Tables
390 Director 2/64 Service Manual
Explanation: The thermal sensor associated with a CTP2 card indicates the warm temperature
threshold was reached or exceeded.
Action: Replace the indicated CTP2 card with a functional card. Perform the data collection
procedure and return the backup CD and faulty card to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error
Indicator
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 811
Message: Critically hot temperature warning (CTP2 card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a CTP2 card indicates the hot temperature
threshold was reached or exceeded.
Action: Replace the indicated CTP2 card with a functional card. Perform the data collection
procedure and return the backup CD and faulty card to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔