FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Event Code Tables
391Director 2/64 Service Manual
Event Code: 812
Message: CTP2 card shutdown due to thermal violation.
Severity: Major.
Explanation: A CTP2 card failed and was powered off because of excessive heat. This event
follows an indication that the hot temperature threshold was reached or exceeded
(event code 811). If the active CTP2 card fails, the backup card takes over operation.
If the backup CTP2 card fails, the active card is not impacted.
Action: Replace the failed CTP2 card with a functional card. Perform the data collection
procedure and return the backup CD and faulty card to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔
Event Code: 850
Message: System shutdown due to CTP2 card thermal violations.
Severity: Severe.
Explanation: The director powered off because of excessive thermal violations on the last
operational CTP2 card.
Action: Replace the failed CTP2 card with a functional card. Perform the data collection
procedure and return the backup CD and faulty card to HP support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director HAFM appliance Host
EWS
Event Log
System
Error LED
Event Log E-Mail Call
Home
Sense
Info
Link
Incident
✔✔✔✔✔✔