FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
46 Director 2/64 Service Manual
MAP 0000: Start MAP
This MAP describes initial fault isolation for the Director 2/64. Fault isolation
begins at the HAFM appliance, failed director, Internet-connected personal
computer (PC) running the Embedded Web Server interface, or director-attached
host.
1
Prior to fault isolation, acquire the following information from the customer:
■ A system configuration drawing or planning worksheet that includes the
HAFM appliance, directors, other HP products, and device connections.
■ The location of the HAFM appliance and all directors.
■ The internet protocol (IP) address, gateway address, and subnet mask for the
director reporting the problem.
■ If performing fault isolation using the HAFM appliance:
805 High temperature warning
(SBAR assembly thermal
sensor).
Go to MAP 0500: FRU Failure
Analysis.
806 Critically hot temperature
warning (SBAR assembly
thermal sensor).
Go to MAP 0500: FRU Failure
Analysis.
807 SBAR assembly shutdown due to
thermal violation.
Go to MAP 0500: FRU Failure
Analysis.
810 High temperature warning
(CTP2 card thermal sensor).
Go to MAP 0500: FRU Failure
Analysis.
811 Critically hot temperature
warning (CTP2 card thermal
sensor).
Go to MAP 0500: FRU Failure
Analysis.
812 CTP2 card shutdown due to
thermal violation.
Go to MAP 0500: FRU Failure
Analysis.
850 System shutdown due to CTP2
card thermal violations.
Go to MAP 0500: FRU Failure
Analysis.
Table 5: Event Codes and Corresponding Maintenance Action (Continued)
Event
Code