FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
46 Director 2/64 Service Manual
MAP 0000: Start MAP
This MAP describes initial fault isolation for the Director 2/64. Fault isolation
begins at the HAFM appliance, failed director, Internet-connected personal
computer (PC) running the Embedded Web Server interface, or director-attached
host.
1
Prior to fault isolation, acquire the following information from the customer:
A system configuration drawing or planning worksheet that includes the
HAFM appliance, directors, other HP products, and device connections.
The location of the HAFM appliance and all directors.
The internet protocol (IP) address, gateway address, and subnet mask for the
director reporting the problem.
If performing fault isolation using the HAFM appliance:
805 High temperature warning
(SBAR assembly thermal
sensor).
Go to MAP 0500: FRU Failure
Analysis.
806 Critically hot temperature
warning (SBAR assembly
thermal sensor).
Go to MAP 0500: FRU Failure
Analysis.
807 SBAR assembly shutdown due to
thermal violation.
Go to MAP 0500: FRU Failure
Analysis.
810 High temperature warning
(CTP2 card thermal sensor).
Go to MAP 0500: FRU Failure
Analysis.
811 Critically hot temperature
warning (CTP2 card thermal
sensor).
Go to MAP 0500: FRU Failure
Analysis.
812 CTP2 card shutdown due to
thermal violation.
Go to MAP 0500: FRU Failure
Analysis.
850 System shutdown due to CTP2
card thermal violations.
Go to MAP 0500: FRU Failure
Analysis.
Table 5: Event Codes and Corresponding Maintenance Action (Continued)
Event
Code
Explanation Action