FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
54 Director 2/64 Service Manual
15
Double-click the icon representing the director reporting the problem. The
Hardware View displays. At the Hardware View:
Verify the Director 2/64 Status table is yellow and the director status is Minor
Failure or Redundant Failure.
Inspect FRUs for a blinking red and yellow diamond (failed FRU indicator)
that overlays the FRU graphic.
Does a blinking red and yellow diamond overlay a power supply graphic?
NO YES
A power supply failure is indicated. Go to step 23 to obtain event
codes. If no event codes are found, go to “MAP 0100: Power
Distribution Analysis” on page 71. Exit MAP.
16
Does a blinking red and yellow diamond overlay a UPM card graphic?
NO YES
A UPM card failure is indicated. Go to step 23 to obtain event codes.
If no event codes are found, go to “MAP 0600: UPM Card Failure and
Link Incident Analysis” on page 118. Exit MAP.
17
A blinking red and yellow diamond overlays a control processor (CTP) card,
SBAR assembly, or fan module graphic.
An FRU failure is indicated. Go to step 23 to obtain event codes. If no event codes
are found, go to “MAP 0500: FRU Failure Analysis” on page 110. Exit MAP.