FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
57Director 2/64 Service Manual
22
A link incident may have occurred, but the LIN alerts option is not enabled for the
port, and the attention indicator does not display.
1. At the Hardware View, click Logs > Link Incident Log. The Link Incident
Log displays, as shown in Figure 12.
Figure 12: Link Incident Log
If a link incident occurred, the affected port number is listed with one of the
following messages.
Link interface incident-implicit incident.
Link interface incident-bit-error threshold exceeded.
Link failure-loss of signal or loss of synchronization.
Link failure-not-operational primitive sequence (NOS) received.
Link failure-primitive sequence timeout.
Link failure-invalid primitive sequence received for the current
link state.
Did one of the listed messages display in the Link Incident Log?
YES NO
The director is operational. Exit MAP.
A link incident problem is indicated. Go to step 23 to obtain event codes. If no
event codes are found, go to “MAP 0600: UPM Card Failure and Link Incident
Analysis” on page 118. Exit MAP.