FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
60 Director 2/64 Service Manual
28
Is the power LED (green) at the director front bezel illuminated?
NO YES
↓ Go to step 30.
A faulty power LED is indicated, but director and Fibre Channel port operation is
not disrupted. The LED is connected to the circuitry in a fan module, and the
module must be removed and replaced (“RRP: Redundant Fan Module” on
page 252). Exit MAP.
29
Inspect the director for indications of being powered on, such as:
■ At the front bezel, an illuminated power LED (green) or system error LED
(amber).
■ An illuminated green LED on the active CTP2 card, and illuminated green
PWR OK LEDs on both power supplies.
■ Audio emanations and airflow from cooling fans.
Is the director powered on?
YES NO
↓ A power distribution problem is indicated. Go to step 23 to obtain
event codes. If no event codes are found, go to “MAP 0100: Power
Distribution Analysis” on page 71. Exit MAP.
A faulty power LED is indicated, but director and Fibre Channel port operation is
not disrupted. The LED is connected to the circuitry in a fan module, and the
module must be removed and replaced (“RRP: Redundant Fan Module” on
page 252). Exit MAP.
30
Is the system error LED (amber) at the director front bezel blinking?
YES NO
↓ Go to step 32.