FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
67Director 2/64 Service Manual
46
Port beaconing is enabled.
1. Consult the customer and next level of support to determine the reason port
beaconing is enabled.
2. Disable port beaconing:
a. At the View panel, click Operations at the left side of the panel. The
Operations panel opens with the Port Beaconing page displayed.
b. Click the Beaconing State check box for the port. The check mark
disappears from the box and port beaconing is disabled.
c. Return to the View panel (Port Properties tab).
Continue.
47
At the View panel, does the Operational State field display a Segmented
message?
NO YES
↓ Port segmentation is indicated. Go to step 52 to obtain event codes. If
no event codes are found, go to “MAP 0700: Fabric, ISL, and
Segmented Port Problem Determination” on page 141. Exit MAP.
48
At the View panel, does the Operational State field display a message indicating
a port problem?
NO YES
↓ Go to step 52 to obtain event codes. If no event codes are found, go to
“MAP 0600: UPM Card Failure and Link Incident Analysis” on
page 118. Exit MAP.