FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
73Director 2/64 Service Manual
Is a failure indicated?
YES NO
↓ The director is operational. Exit MAP.
5
Ensure the indicated power supply is correctly installed and seated in the director.
If required, partially remove and reseat the power supply.
Was a corrective action performed?
YES NO
↓ Go to step 7.
6
Verify redundant power supply operation.
1. Inspect the power supply and ensure the green PWR OK LED illuminates
and all amber LEDs extinguish.
2. At the Hardware View, observe the graphic representing the power supply and
ensure a failure symbol (blinking red and yellow diamond) does not display.
Is a failure indicated?
YES NO
↓ The director is operational. Exit MAP.
7
A redundant power supply failed and must be removed and replaced (“RRP:
Redundant Power Supply” on page 245).
■ This procedure is concurrent and can be performed while director power is on.
■ Perform the data collection procedure as part of FRU removal and
replacement.
Note: Do not remove a power supply unless a replacement is immediately available.
To avoid director overheating, a power supply must be replaced within five minutes.