FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
77Director 2/64 Service Manual
Is a dual power supply failure still indicated?
YES NO
The director is operational. Exit MAP.
17
Both power supplies failed and must be removed and replaced (“RRP: Redundant
Power Supply” on page 245). Perform the data collection procedure as part of
FRU removal and replacement.
Did dual power supply replacement solve the problem?
NO YES
The director is operational. Exit MAP.
A dual power supply failure is not confirmed. Replace both original power
supplies to avoid the cost of expending replacement FRUs. Continue.
18
A power module assembly failure is indicated and must be removed and replaced
(“RRP: Power Module Assembly” on page 255). This procedure is
non-concurrent and must be performed while director power is off.
Did power module assembly replacement solve the problem?
NO YES
The director is operational. Exit MAP.
A power module assembly failure is not confirmed. Replace the original power
module assembly to avoid the cost of expending a replacement FRU. Continue.
19
One or both power supplies are operational, but logic cards are not receiving DC
power. In-card circuit breakers for all logic cards may have tripped due to a power
surge, or the backplane failed.
Power cycle the director to reset all logic cards (“Power-On Procedure” on
page 200).
Did power cycling the director solve the problem?
NO YES
The director is operational. Exit MAP.