FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
78 Director 2/64 Service Manual
20
The backplane failed and must be removed and replaced (“RRP: Backplane” on
page 258).
■ This procedure is non-concurrent and must be performed while director power
is off.
■ Perform the data collection procedure as part of FRU removal and
replacement.
Did backplane replacement solve the problem?
NO YES
↓ The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
21
Is fault isolation being performed at the HAFM appliance?
YES NO
↓ Fault isolation is being performed at the Embedded Web Server
interface. Go to step 25.
22
At the Hardware View, does a yellow triangle display at the alert panel and a
blinking red and yellow diamond (failed FRU indicator) display over a power
supply graphic?
NO YES
↓ A redundant power supply failed. Go to step 7.
23
At the Hardware View, does a grey square display at the alert panel, a No Link
status displays at the director Status table, and graphical FRUs are uninstalled?
YES NO
↓ A green circle displays at the alert panel and the director is
operational. Exit MAP.