FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
82 Director 2/64 Service Manual
2
Was an event code 400, or 411, or 413 observed at the director Event Log (HAFM
appliance) or at the Embedded Web Server Event Log?
YES NO
Analysis for the failure is not described in this MAP. Go to “MAP
0000: Start MAP” on page 46. Exit MAP.
3
Table 7 lists event codes, brief explanations of the codes, and the associated steps
that describe fault isolation procedures.
4
POST/IPL diagnostics detected an FRU failure as indicated by an event code 400
with supplementary event data.
1. At the Hardware View, click Logs > Event Log. The Event Log displays.
2. Examine the first two bytes (0 and 1) of event data.
Byte 0 is an FRU code that indicates the failed component. Byte 1 is the slot
number of the failed FRU (00 for a nonredundant FRU, 00 or 01 for redundant
FRUs, and 00 through 15 for UPM cards).
Table 8 lists byte 0 FRU codes and associated steps that describe fault
isolation procedures.
Table 7: MAP 0200: Event Codes
Event Code Explanation Action
400 Power-up diagnostic failure. Go to step 4
411 Firmware fault. Go to step 11
413 Backup CTP2 card POST
failure.
Go to step 12
Table 8: Byte 0 FRU Codes
Byte 0 Failed FRU Action
01 Backplane. Go to step 5
02 CTP2 card. Go to step 6
03 SBAR assembly. Go to step 7