FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
82 Director 2/64 Service Manual
2
Was an event code 400, or 411, or 413 observed at the director Event Log (HAFM
appliance) or at the Embedded Web Server Event Log?
YES NO
↓ Analysis for the failure is not described in this MAP. Go to “MAP
0000: Start MAP” on page 46. Exit MAP.
3
Table 7 lists event codes, brief explanations of the codes, and the associated steps
that describe fault isolation procedures.
4
POST/IPL diagnostics detected an FRU failure as indicated by an event code 400
with supplementary event data.
1. At the Hardware View, click Logs > Event Log. The Event Log displays.
2. Examine the first two bytes (0 and 1) of event data.
Byte 0 is an FRU code that indicates the failed component. Byte 1 is the slot
number of the failed FRU (00 for a nonredundant FRU, 00 or 01 for redundant
FRUs, and 00 through 15 for UPM cards).
Table 8 lists byte 0 FRU codes and associated steps that describe fault
isolation procedures.
Table 7: MAP 0200: Event Codes
Event Code Explanation Action
400 Power-up diagnostic failure. Go to step 4
411 Firmware fault. Go to step 11
413 Backup CTP2 card POST
failure.
Go to step 12
Table 8: Byte 0 FRU Codes
Byte 0 Failed FRU Action
01 Backplane. Go to step 5
02 CTP2 card. Go to step 6
03 SBAR assembly. Go to step 7