FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
84 Director 2/64 Service Manual
Did CTP2 card replacement solve the problem?
NO YES
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
7
An SBAR assembly failed POSTs (indicated by a 03 FRU code) and must be
removed and replaced (“RRP: Redundant SBAR Assembly” on page 248).
This procedure is concurrent and can be performed while director power is on.
Perform the data collection procedure as part of FRU removal and
replacement.
Did SBAR assembly replacement solve the problem?
NO YES
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
8
A fan module failed POSTs (indicated by a 05 FRU code) and must be removed
and replaced (“RRP: Redundant Fan Module” on page 252).
This procedure is concurrent and can be performed while director power is on.
Perform the data collection procedure as part of FRU removal and
replacement.
Note: Do not remove a fan module unless the replacement module is available.
Operation of the director with only one fan module for an extended period may cause
one or more thermal sensors to post event codes.
Did fan module replacement solve the problem?
NO YES
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.