FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
85Director 2/64 Service Manual
9
A power supply failed POSTs (indicated by a 06 FRU code) and must be removed
and replaced (“RRP: Redundant Power Supply” on page 245).
This procedure is concurrent and can be performed while director power is on.
Perform the data collection procedure as part of FRU removal and
replacement.
Note: Do not remove a power supply unless a replacement is immediately available.
To avoid director overheating, a power supply must be replaced within five minutes.
Did power supply replacement solve the problem?
NO YES
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
10
A UPM card failed POSTs (indicated by a 08 through 0F FRU code) and must be
removed and replaced (“RRP: UPM Card” on page 236).
This procedure is concurrent and can be performed while director power is on.
Perform the data collection procedure as part of FRU removal and
replacement.
Did UPM card replacement solve the problem?
NO YES
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
11
POST/IPL diagnostics detected a firmware failure (as indicated by an event code
411) and performed an online dump. All Fibre Channel ports reset after the failure
and devices momentarily log out, log in, and resume operation.
Perform the data collection procedure and return the information to HP for
analysis by third-level support personnel. Exit MAP.