FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)
Diagnostics
96 Director 2/64 Service Manual
2
Table 9 lists event codes, brief explanations of the codes, and associated steps that
describe fault isolation procedures.
3
Is fault isolation being performed at the HAFM appliance?
YES NO
↓ Fault isolation is being performed through the Embedded Web Server
interface. Go to step 24.
4
At the HAFM main window, is a grey square with yellow exclamation mark
associated with the icon representing the director reporting the problem?
YES NO
↓ The director-to-HAFM appliance connection is restored and is
operational. Exit MAP.
The grey square indicates the HAFM appliance cannot communicate with the
director because:
■ The director-to-HAFM appliance Ethernet link failed.
■ AC power distribution in the director failed, or AC power was disconnected.
■ Both of the director’s CTP2 cards failed.
Continue.
Table 9: MAP 0400: Event Codes
Event Code Explanation Action
430 Excessive Ethernet transmit
errors.
Go to step 8
431 Excessive Ethernet receive
errors.
Go to step 8
432 Ethernet adapter reset. Go to step 14