FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director 2/64 Service Manual (AA-RS2ED-TE, July 2004)

Diagnostics
99Director 2/64 Service Manual
10
If appropriate, verify that the hubs are correctly daisy-chained, as shown in
Figure 21.
Figure 21: Ethernet Hubs, Daisy-Chained
Note: To check two hubs, use step 1 and step 2 (top and middle hub instructions
only).
1. At the first (top) Ethernet hub, ensure an RJ-45 Ethernet patch cable connects
to port 24 and the medium-dependent interface (MDI) switch is set to MDI
(in).
2. At the middle Ethernet hub, ensure the patch cable from the top hub connects
to port 12, the patch cable from the bottom hub connects to port 24, and the
MDI switch is set to MDI (in).
3. At the bottom Ethernet hub, ensure the patch cable from the middle hub
connects to port 12 and the MDI switch is set to MDIX (out).