FW V06.XX/HAFM SW V08.02.00 HP StorageWorks Director Element Manager User Guide (AA-RTDUC-TE, July 2004)
Table Of Contents
- Contents
- About this Guide
- Overview
- Feature Keys
- Managing the Director
- Element Manager Description
- Using the Element Manager
- Backing Up and Restoring Element Manager Data
- Monitoring and managing the Director
- Hardware View
- Port Card View
- Port List View
- Node List View
- Performance View
- FRU List View
- Port Operational States
- Link Incident Alerts
- Threshold Alerts
- Configuring the Director
- Configuring Identification
- Configuring Management Style
- Configuring Operating Parameters
- Configuring a Preferred Path
- Configuring Switch Binding
- Configuring Ports
- Configuring Port Addresses (FICON Management Style)
- Configuring an SNMP Agent
- Configuring Open Systems Management Server
- Configuring FICON Management Server
- Configuring Feature Key
- Configuring Date and Time
- Configuring Threshold Alerts
- Creating New Alerts
- Figure 49: Configure Threshold Alert(s) dialog box
- Figure 50: New Threshold Alerts dialog box - first screen
- Figure 51: New Threshold Alerts dialog box - second screen
- Figure 52: New Threshold Alerts dialog box - third screen
- Figure 53: New Threshold Alerts dialog box - summary screen
- Figure 54: Configure Threshold Alerts dialog box - alert activated
- Modifying Alerts
- Activating or Deactivating Alerts
- Deleting Alerts
- Creating New Alerts
- Configuring Open Trunking
- Exporting the Configuration Report
- Enabling Embedded Web Server
- Enabling Telnet
- Backing Up and Restoring Configuration Data
- Using Logs
- Using Maintenance Features
- Optional Features
- Information and Error Messages
- Index

Using Logs
172 Director Element Manager User Guide
■ Severity—There are four classifications of severity that identify the
importance of the event.
— 0=Informational
—2=Minor
—3=Major
— 4=Severe (not operational)
■ FRU Position—An acronym representing the FRU type, followed by a
number representing the FRU chassis position. FRU acronyms are:
— BKPLNE—backplane
— CTP—CTP card
— SBAR—SBAR card
— Port—card
— FAN—fan module
— PWR—power supply
The chassis (slot) position for a non-redundant FRU is 0. The chassis
positions for redundant FRUs are 0, 1, and 2. The chassis positions for port
cards are 0 through 35, and slot 32 is unavailable.
■ Event Data—Up to 32 bytes of supplementary information for the event in
hexadecimal format. For detailed information on event data and problem
resolution, refer to the event code tables appendix in the HP StorageWorks
Director 2/64 Service Guide for the Director 2/64 and the HP StorageWorks
Director 2/140 Service Guide for the Director 2/140.