Using Logs
172 Director Element Manager User Guide
Severity—There are four classifications of severity that identify the
importance of the event.
0=Informational
—2=Minor
—3=Major
4=Severe (not operational)
FRU Position—An acronym representing the FRU type, followed by a
number representing the FRU chassis position. FRU acronyms are:
BKPLNE—backplane
CTP—CTP card
SBAR—SBAR card
Port—card
FAN—fan module
PWR—power supply
The chassis (slot) position for a non-redundant FRU is 0. The chassis
positions for redundant FRUs are 0, 1, and 2. The chassis positions for port
cards are 0 through 35, and slot 32 is unavailable.
Event Data—Up to 32 bytes of supplementary information for the event in
hexadecimal format. For detailed information on event data and problem
resolution, refer to the event code tables appendix in the HP StorageWorks
Director 2/64 Service Guide for the Director 2/64 and the HP StorageWorks
Director 2/140 Service Guide for the Director 2/140.