HP StorageWorks B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 10.3.4 Release Notes (5697-0436, April 2010 - includes all 10.3.x versions)

SolutionClosed defect summary
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Use an M-EOS based switch as the
seed switch.
If an FOS-based switch is used as a seed switch in an interop fabric
with an Mi10K, and the Mi10K is discovered with an IPv6 address,
it cannot be managed by DCFM.
Fixed in DCFM 10.3.0
Fabric updates involving switches in Access Gateway mode do not
appear in the Product List.
Fixed in DCFM 10.3.0
The DCFM Administrator's Guide and Online help do not indicate that
discovery of a pure Secure FOS fabric in strict mode is not supported.
Fixed in DCFM 10.3.0
After migrating from EFCM to DCFM, if you log in as a user, the Topo-
logy view is unavailable to you.
Fixed in DCFM 10.3.0
Devices attached to switches in Access Gateway mode are not dis-
played in the Topology view.
Fixed in DCFM 10.3.0
The Topology is not updated when a (10 GbE) TE port is enabled or
disabled.
Fixed in DCFM 10.3.0
Detailed information about the Logical Switch Configuration and
Storage Encryption Key Operation privileges is missing from the user
privileges table in the Online Help and functional specification.
Fixed in DCFM 10.3.0
After migrating from M-EOS 9.7.3, the ISLs take a long time to appear
in the Topology.
Fixed in DCFM 10.3.0
If you right-click a 10 GbE (TE) port, and then click Modify, the Port
Administration WebTools dialog does not launch in the context of the
selected entity.
Fixed in DCFM 10.3.0
ISLs between two switches, if one is in Access Gateway mode, do not
appear in the Topology view.
Fixed in DCFM 10.3.0
There is a switch name mismatch between WebTools and DCFM in
the Device Tree.
Fixed in DCFM 10.3.0
ISLs do not appear in the Topology if the seed switch is changed from
a switch running a version of FOS earlier than 6.1 to a nondefault lo-
gical switch.
Fixed in DCFM 10.3.0
If an error occurs during the FICON Merge wizard, and the window
is resized, you cannot use the scroll bar to see the message. Instead,
you must cut and paste the message into a text editor to read it.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Change the FTP server configuration
to Internal, and then restart the
server.
After upgrading DCFM 10.0.2 to DCFM 10.1.3, opening the Logical
Switches dialog returns the message Error fetching data from
server for all chassis.
Fixed in DCFM 10.3.0Logic is reversed when configuring an end-to-end monitor pair.
Fixed in DCFM 10.3.0
After migrating from EFCM to DCFM, imported switch firmware in
EFCM is missing from the DCFM firmware repository.
28