HP StorageWorks B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 10.3.4 Release Notes (5697-0436, April 2010 - includes all 10.3.x versions)

SolutionClosed defect summary
Fixed in DCFM 10.3.0
On the Firmware Management dialog Download tab, the Overwrite
Current Firmware check box is selected by default, but it should not
be.
Fixed in DCFM 10.3.0
M-EOS-based switches should be filtered from the source list in the
Replicate Switch Configuration dialog because they are not supported
for this function.
Fixed in DCFM 10.3.0
When an Access Gateway switch is connected to multiple fabrics, an
incorrect fabric name appears in the Ports table.
Fixed in DCFM 10.3.0
The ghost image and yellow dash line are not displayed for a storage
array when the storage port is segmented. This could mislead admin-
istrators if they are unaware of the segmented device.
Fixed in DCFM 10.3.0
In the Fabric Summary Report, Switch Detail section, the Switch Type
for the HP StorageWorks Encryption SAN Switch occupies too much
space, causing the Port Number and Switch Name to be placed incor-
rectly.
Fixed in DCFM 10.3.0
After migrating from EFCM to DCFM with an Access Gateway switch
configured, an extra HBA icon is displayed in the Topology with the
same WWN as the Access Gateway switch.
Fixed in DCFM 10.3.0
Performance sample values are purged before the table gets the defined
number of samples in the database, and the user cannot retrieve all
values for the defined timeframe.
Fixed in DCFM 10.3.0
An incorrect error message is displayed if a user attempts to copy an
empty view.
Fixed in DCFM 10.3.0
The CNA icon displayed in the Connectivity Map does not match the
icon displayed in the Device Tree.
Fixed in DCFM 10.3.0
In the Fabric Summary Report, Device Information section, the Storage
Devices name connected to the switch is not displayed.
Fixed in DCFM 10.3.0
After a port is blocked, yellow dotted lines are incorrectly shown for
other port connectivity.
Fixed in DCFM 10.3.0
When a Backup fails for the default drive, a Real Backup Medium
message is incorrectly displayed in the Master Log.
Fixed in DCFM 10.3.0
The connection between an Access Gateway switch and connected
switch is not displayed in the Topology.
Fixed in DCFM 10.3.0
The Master Log stops updating email notification-related events, even
though events that should be logged continue to occur.
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Click OK to close the error message
and progress bar.
In an interop/mixed fabric, the progress bar and an error message
are shown simultaneously when opening the Zoning dialog.
Fixed in DCFM 10.3.0
The Tooltip flyover for devices that can act both as Initiator and a
Target shows an incorrect device type.
Fixed in DCFM 10.3.0
DCFM client reponse is very slow, resulting in a long duration to open
any dialogs.
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional 31