FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric Manager Release Notes (AA-RUR6G-TE, August 2005)

Upgrading from an ea
rlier version of rmware
Upgrading to rmwa
re 07.01.02-4 is non-disruptive to attached devices. The director
or edge switch is no
trequiredtobeofine before performing an upgrade operation.
Limitations to up
grades are clearly identied if there are any limitations to performing
the operation.
Before upgrading rmware, it is highly recommended that you back up the director or
edge switch congu ration. Refer to your HP StorageWorks director or edge switch
Element Manager user guide for more information. Em bedded Web Server (EWS)
also provides an option to p rint or save product conguration to a le. Refer to the
HP StorageWorks Embedded Web Server User Guide for more information.
All products must be running rmware 06.00.00 or later before upgrading to
07.01.02-4. If a switch is operating with a rmware level earlier than 06.00.00, you
mustupgradeto06.xx.xxbeforeinstalling07.01.02-4.
Upgrades and downgrades are supported only from one major release to the next, such
as from 06.xx.xx to 07.01.02-4. If EWS is used for upgrades and downgrades, and this
rule is not followed, errors occur and there may be a disruption to attached devices.
If upgradi
ng to rmware 06.02 .00-22 requires you to upgrade from 04.xx.xx to
05.xx.xx in the process, there are special considerations:
For directors, refer to Upgrading rmware on a director from 04.xx.xx to
05.xx.xx
For edge switches, refer to Upgrading rmware on an edge switch from 04.xx.xx
to 05.xx.xx
Asmalln
umber of early-shipped Surestore Director FC-64 units may receive one of the
following messages when they upgrade to rmware 05.02.00-13:
HAFM—Firmware cannot be loaded due to insufcient CTP memory.
EWS—Fi
le System Error: Insufcient memory for new rmware version.
This occurs only in certain u nits with CTP cards. Units with CTP2 cards do not have
this issue.
If you g
et one of these messages during the upgrade, the rmware upgrade failed, but
the uni
t continues working with the existing rmware without an interruption in ser vice.
The up
grade process checks for sufcient memory before a ctivating the new rmware
imag
e. The rmware upgrade does not complete without sufcient memory. Please
cont
act HP Customer Support if you receive this message.
HA-Fabric Manager release notes