FW 07.01.02/HAFM SW 08.06.00 HP StorageWorks HA-Fabric Manager Release Notes (AA-RUR6G-TE, August 2005)

Ethernet port on HAFM appliance may encounter problems
When you use TightV
NC to access the HAFM appliance and you are running HAFM
locally on the HAFM appliance, the Ethernet p ort on the HAFM appliance can appear
to hang. When the Ethernet port encounters problems, the following m ay o ccur:
There is an appare
nt loss of communication to switches being managed by
HAFM.
The appliance CPU usage and memory usage display abnormally h igh readings.
Workaround
If this condition persists, it may be necessary to reboot the HAFM appliance. This is not
disruptive to managed switches, but monitoring and logging functions are interrupted
while the appliance is rebooting.
Exporting an XML topology is not successful for all views
Exporting an XML topology only exports fabric information. For example, exporting an
XML top ology of a user-dened view displaying a connected set or isolated devices
results in an e
mpty XML document.