HP StorageWorks EFS WAN Accelerator 3.0.12 release notes (AG421-96009, April 2009)
HP System Management Homepage
When logging in to the HP System Management Homepage, use the admin login only; do not attempt
to use a Radius or TACACS+ login.
The login page of the HP System Management Homepage does not allow a blank password. Set the
admin account password before attempting to login to the HP System Management Homepage.
When sending test traps from the HP System Management Homepage (Settings > SNMP Webagent
> SNMP Configuration), only version 1 traps are sent. Set a version 1 trap destination using the general
system Management Console (Setup > Reports > SNMP Trap Receivers) before attempting to send a
test trap using the HP System Management Homepage.
HP Integrated Lights-Out network settings
Modifying settings using the web-based interface of the HP Integrated Lights-Out (iLO) Network Settings
page (Administration > Network Settings) can result in the system locking up. If Automatic Server
Recovery (ASR) is enabled, the system will reboot after the ASR timeout value (see the system's
ROM-Based Setup Utility (RBSU) to determine if ASR is enabled.) To avoid this, access the WAN
Accelerator Manager command-line interface (CLI) and issue the following commands prior to modifying
network settings on iLO:
enable
configure terminal
hp agents stop
Then, modify the network settings on iLO. After you have finished modifying the network settings, start
the HP agents using the CLI:
hp agents start
An alternative is to modify the iLO settings using the iLO RBSU, available during system boot. See the
HP Integrated Lights-Out home page at http://www.hp.com/servers/lights-out for information about
iLO, and the HP ROM-Based Setup Utility user guide on the documentation CD for information about
RBSU.
Shutting down the system
When shutting down the system using the web-based interface or the command-line interface, the
system will not automatically power down. A few minutes after the shutdown command is issued, the
system goes into a mode that is safe to power down by using the power button.
Reverting from version 3.x to 2.x
When reverting from EFS WAN Accelerator version 3.x to version 2.x, you need to either clean the
data store on reboot, or run the following commands once you have logged into the CLI (before
rebooting to version 2.x):
enable
configure terminal
HP StorageWorks EFS WAN Accelerator 3.0.12 release notes 9