HP StorageWorks Enterprise File Services WAN Accelerator 2.1.7 Command-Line Interface Reference Manual (392361-004, June 2006)

HP STORAGEWORKS EFS WAN ACCELERATOR COMMAND-LINE INTERFACE REFERENCE MANUAL 53
3 - ENABLE-MODE COMMANDS
NSPI Port: 7840
MAPI/Exchange 2003 Support: yes
show protocol ms-sql
Description Displays the Microsoft Structured Query Language (MS-SQL) blade support settings.
Syntax show protocol ms-sql
Parameters None
Example
minna # show protocol ms-sql
Enable entire MS-SQL blade: yes
MS-SQL server port: 1433
MS-SQL number of preacknowledgement: 5
MS-SQL prefetch fetch-next: yes
show protocol ms-sql rules
Description Displays the MS-SQL rules.
Syntax show protocol ms-sql rules
Parameters None
Example
minna # show protocol ms-sql rules
MS-SQL RPC Rule
Rule ID App Name RPC ID RPC Name Num Params RPC Query Cursor Type
------- -------- ------ -------- ---------- --------- -----------
1 Microsoft\(R\) Project for Windows\(TM\) 0 sp_ddopen 9
MS-SQL RPC Arg Rule
Arg-Offset Expr
---------- --------------------------------------------------------
1 sp_tables
5 MSP_PROJECTS
MS-SQL RPC Action
Action ID Num Reps Invalidate Miss Policy Prefetch Preack
--------- -------- ---------- ----------- -------- ------
1 1 flush-all 0 true true
MS-SQL RPC Arg Action Rule
Arg-Offset Expr
---------- --------------------------------------------------------
5 replace MSP_NUMBER_FIELDS
MS-SQL RPC Action
Action ID Num Reps Invalidate Miss Policy Prefetch Preack
--------- -------- ---------- ----------- -------- ------
2 1 flush-all 0 true true
MS-SQL RPC Arg Action Rule
Arg-Offset Expr
---------- --------------------------------------------------------
5 replace MSP_TEXT_FIELDS
MS-SQL RPC Action
Action ID Num Reps Invalidate Miss Policy Prefetch Preack
--------- -------- ---------- ----------- -------- ------
3 1 flush-all 0 true true
MS-SQL RPC Arg Action Rule
rg-Offset Expr
---------- --------------------------------------------------------