HP StorageWorks Enterprise File Services WAN Accelerator 2.1.7 Command-Line Interface Reference Manual (392361-004, June 2006)

84 4 - CONFIGURATION-MODE COMMANDS
datastore sync port
Description Sets the port for the peer HP EFS WAN Accelerator for which you want to replicate
data on.
Syntax datastore sync port <port>
Parameters
Example
minna (config) # datastore sync port 1234
minna (config) #
datastore sync reconnect
Description Sets the reconnection interval for data store synchronization. The no command option
disables the reconnection interval.
Syntax datastore sync reconnect <seconds>
Parameters
Example
minna (config) # datastore sync reconnect 30
minna (config) #
datastore sync server
Description Sets the data store synchronization server. The no command option disables the
synchronization server.
Syntax datastore sync server
Parameters None
Example
minna (config) # datastore sync server
minna (config) #
email domain
Description Set the domain for email notifications. Use the email domain command only if the
email address does not contain the domain. The no command option disables the
email domain.
Syntax email domain <hostname or IP address>
<port> Specifies the port of the peer HP EFS WAN Accelerator. The default value
is 7744.
<seconds> Specifies the number of seconds for the reconnection interval. The default
value is 30.