DCFM Enterprise User Manual (53-1001775-01, June 2010)

DCFM Enterprise User Manual 219
53-1001775-01
Viewing port optics
8
Viewing port optics
To view port optics, complete the following steps.
1. Right-click the switch for which you want to view port optic information on the Connectivity Map
and select Port Optics (SFP).
The Port Optics (SFP) dialog box displays(Figure 95).
FIGURE 95 Port Optics dialog box
2. Review the port optics information.
Slot/Port #—The slot and port number of the selected fabric.
FC Address—The Fibre Channel address of the port.
TX Power—The power transmitted to the SFP in dBm and uWatts.
NOTE
The uWatts display requires devices with Fabric OS 6.1.0 and later. Devices running Fabric
OS 6.0.0 and earlier only display dBm.
RX Power—The power received from the port in dBm and uWatts.
NOTE
The uWatts display requires devices with Fabric OS 6.1.0 and later. Devices running Fabric
OS 6.0.0 and earlier only display dBm.
Transceiver Temp—The temperature of the SFP transceiver.
Vendor—The vendor of the SFP.
Vendor OUI—The vendor’s organizational unique identifier (OUI).
FC Speed—The FC port speed; for example, 400 Mbps.
Distance—The length of the fiber optic cable.