DCFM Enterprise User Manual (53-1001775-01, June 2010)

DCFM Enterprise User Manual 477
53-1001775-01
Configuring a cascaded FICON fabric
18
Configuring a cascaded FICON fabric
NOTE
If you receive a 'FICON not supported on switch' error, refer to FICON troubleshooting for a list of
possible causes.
The FICON wizard automatically creates high integrity fabric configuration settings that support a
cascaded FICON fabric.
1. Select Configure > FICON > Configure Fabric.
The Configure Cascaded FICON Fabric screen of the FICON Configuration dialog displays
(Figure 203).
FIGURE 203 Configure Cascaded FICON Fabric dialog box
2. Use the Fabric drop-down selector to select the fabric you want to configure.
NOTE
(Fabric OS switches only) All switches in a fabric must be running Fabric OS version 5.2 or later.
If a Fabric OS version earlier than version 5.2 is present in the topology, the fabric is not listed.
3. Select the FMS Mode check box to manage the fabric by a host-based management program
using FICON CUP protocol.
If you select FMS Mode, each switch is checked for a CUP license. Any switches that do not
have a CUP license are listed, with a reminder that a CUP license is necessary to communicate
with the fabric management server.