DCFM Enterprise User Manual (53-1001775-01, June 2010)

DCFM Enterprise User Manual 29
53-1001775-01
Feature-to-firmware requirements
1
8. Go to the Install_Home/conf directory.
9. Open the version.properties file in a text editor.
10. Change the patch version (patch.version) value to the reverted patch (for example, if you are
reverting from patch F to patch C then
patch.version = c).
If the previous version is the initial version (no patches), change the patch version value to
none (for example,
patch.version = None).
11. Go to the Install_Home/patch-backup/conf directory.
12. Copy the patch.conf file in this directory to the Install_Home/conf directory.
If the previous version is the initial version (no patches), delete the patch.conf file in the
Install_Home/conf directory.
13. Start all services by completing the following steps.
a. Launch the Server Console.
b. Click the Services tab.
c. Click Start to start all services.
Feature-to-firmware requirements
Use the following table to determine whether the Management application features are only
available with a specific version of the Fabric OS firmware, M-EOS firmware, or both, as well as if
there are specific licensing requirements.
Feature Fabric OS M-EOS
Access Gateway (AG) AG connected to Fabric OS devices requires
firmware 6.1.1 or later.
AG connected to M-EOS devices requires firmware
9.9.2 or later.
Call Home Requires Fabric OS 5.2 or later for supportSave.
Requires Fabric Watch license for SNMP traps.
Requires M-EOS and M-EOSn 9.6.X or later.
Discovery Requires Fabric OS 5.0 or later for the seed switch
in a pure Fabric OS fabric.
Requires Fabric OS 6.0 or later for the seed switch
in a mixed Fabric OS and M-EOS fabric.
Requires M-EOS 9.9.2 or later for the seed switch
in a pure M-EOS fabric.
Requires M-EOS and M-EOSn 9.6.X or later for
discovery.
Encryption Requires Fabric OS 6.1.1_enc. Not available.
Enhanced Group Management Requires Enhanced Group Management license. Not available.
Fault Management Requires Fabric OS 4.4 or later for SNMP traps Requires M-EOS and M-EOSn 9.6.X or later.
Fabric Binding Requires Fabric OS 5.2 or later in a pure Fabric OS
fabric.
Requires Fabric OS 6.0 or later in a mixed
Fabric OS and M-EOS fabric.
Requires M-EOS and M-EOSn 9.6.X or later.
FCIP Management Requires Fabric OS 5.1 or later to modify.
Requires Fabric OS 5.3 or later for FCIP tunnels.
Requires FCIP license.
Requires Fabric OS 6.0 or later to enable the
FICON Emulation tab on the FCIP Tunnel
Advanced Settings dialog box.
Not available.