38 DCFM Enterprise User Manual
53-1001775-01
Discovering fabrics
2
6. Click the SNMP tab (Figure 20).
FIGURE 20 Address Properties dialog box (SNMP - v1 tab)
7. Enter the duration (in seconds) after which the application times out in the Time-out (sec) field.
8. Enter the number of times to retry the process in the Retries field.
9. Select the SNMP version from the SNMP Version list.
If you selected v1, continue with step 10.
If you select v3, the SNMP tab displays the v3 required parameters. Go to step 14.
To discover a Fabric OS device (not virtual fabric-capable), you must provide the existing
SNMP v3 username present in the switch.
To discover a Virtual Fabric device, you must configure SNMP v3 and your SNMP v3 user
account must be defined as a Fabric OS switch user.
NOTE
When you discovers Virtual Fabric-enabled switch with the SNMP v3 username “admin”,
which is the same as the Fabric OS switch user, the Management application
automatically creates an SNMP username “admin” in the switch by replacing the sixth
username.
10. Specify the Read option by selecting Default ‘public’ or Custom.
11. If you selected Custom, enter the community string in the Custom and Confirm Custom fields.
12. Specify the Write option by selecting Default ‘private’ or Custom.
13. If you selected Custom, enter the community string in the Custom and Confirm Custom fields.
Go to step 21.