DCFM Professional Plus User Manual (53-1001774-01, June 2010)

560 DCFM Professional Plus User Manual
53-1001774-01
19
1. Select a switch on the Product List or Connectivity Map and select Configure > Logical
Switches.
The Logical Switches dialog box displays.
2. Select the physical chassis from which you want to assign ports in the Chassis list.
3. Select the ports you want to include in the logical switch from the Ports table.
4. Right-click anywhere in the Existing Logical Switches table and select Table > Expand All.
5. Select the logical switch in the Existing Logical Switches table.
6. Click the right arrow button.
The ports display in the selected logical switch node in the Existing Logical Switches table.
7. Click OK on the Logical Switches dialog box.
The Logical Switch Change Confirmation and Status dialog box displays with a list of all
changes you made in the Logical Switches dialog box.
NOTE
Ports are disabled before moving from one logical switch to another.
8. Select the Re-Enable ports after moving them check box.
9. (Optional) Select the Unbind Port Addresses while moving them check box.
10. Click Start to send these changes to the affected chassis.
NOTE
Most changes to logical switches will disrupt data traffic in the fabric.
The status of each change is displayed in the Status column and Status area in the dialog box.
11. When the changes are complete, click Close.
Removing ports from a logical switch
1. Select a switch on the Product List or Connectivity Map and select Configure > Logical
Switches.
The Logical Switches dialog box displays.
2. Select the physical chassis to which the ports belong in the Chassis list.
3. Right-click anywhere in the Existing Logical Switches table and select Table > Expand All.
4. Select the ports you want to remove from the logical switches from the Existing Logical
Switches table.
5. Click the left arrow button.
A message displays indicating that the ports will be moved to the default logical switch.
6. Click OK on the DCFM Warning message.
The selected ports are removed from the logical switch and automatically reassigned to the
default logical switch. The selected ports are highlighted in the Ports table.